Customization: | Available |
---|---|
After-sales Service: | Life Time |
Warranty: | 24 Months Free |
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
The TGA analyzer, also known as the Proximate Analyzer, is used to measure the moisture, ash and volatile matter of coal, coke, petroleum and other substances, and automatically calculate their calorific value, fixed carbon and hydrogen content
The MCPC control module and touch screen are used to monitor the status of the instrument in real time, save the instrument parameters, and the test process is completed independently without the intervention of the upper computer, realizing offline operation and self diagnosis reminder of the instrument, greatly improving the reliability of the instrument;
Stepping motor and high-precision angle encoder control system are adopted, with accurate positioning and fast sample weighing;
Automatic sample weighing, automatic identification of moisture drying, automatic calculation, storage and printing of results. Built in precision electronic balance, stable and reliable weighing;
PID temperature control algorithm is adopted, with higher temperature control accuracy;
Nitrogen drying method or air drying method can be adopted;
With power off memory function, the test data will not be lost if the test process is interrupted accidentally, and the test can be completed automatically after power on;
Dry fired electric heating tube is used for heating, blast drying, and all stainless steel liner, with good reflectivity and uniform furnace temperature;
Inspection drying can be carried out, and the inspection drying time can be customized;
The standard test time can be used, which fully conforms to the arbitration method, and the results can be used for legal arbitration;
It can be connected to the laboratory management system to ensure that the balance data does not fall to the ground, and the test results are backed up and uploaded.
The MCPC control module and balance display module are used to monitor the instrument status in real time, save the instrument parameters, and the test process is completed independently without the intervention of the upper computer, realizing offline operation and instrument self diagnosis reminder, greatly improving the reliability of the instrument;
Stepping motor and high-precision angle encoder control system are adopted, with accurate positioning and fast sample weighing;
With power off memory function, the test data will not be lost if the test process is interrupted accidentally, and the test can be completed automatically after power on;
Adopt distributed intelligent smoke exhaust interface, which can exhaust smoke and dust more effectively and is more environmentally friendly;
PID temperature control algorithm is adopted, with higher temperature control accuracy;
The testing process, conditions and results of moisture, ash and volatile matter meet the requirements of national standards, and the results of moisture and ash are superior to the requirements of national standards, so no correction is required;
Multi furnace double balance structure is adopted, which can be combined or measured independently without external air source;
Automatic flap device is adopted to avoid operators from high temperature radiation and scald;
Adopt thermogravimetric analysis method, automatically weigh samples, automatically send samples, automatically process data, calculate results, print and store reports, etc. to realize unattended operation;
The heat insulation device is added at the bottom of the high-temperature furnace to reduce the thermal radiation, ensure that the coal sample is not oxidized, and the temperature control in the constant temperature room is more accurate;
It can be connected to the laboratory management system to ensure that the balance data does not fall to the ground, and the test results are backed up and uploaded.
Model | MJ-PA-5 | MJ-PA-4 | MJ-PA-3 | MJ-PA-2 | MJ-PA-1 |
Temperature range | RT+10~1000ºC; ±2ºC | ||||
Test items | Moisture, ash, volatilization | Moisture, ash, | volatilization | Moisture, ash, volatilization | Moisture, Loss on ignition |
Test temperature | Moisture-105ºC, ash-815ºC, volatilization-900ºC, Loss on ignition -600ºC | ||||
Accuracy | Within the uncertainty range of the standard sample | ||||
Sample mass | 0.5~1.2g | 5-20g | |||
Batch processing capacity | 20pcs | 10pcs | |||
Test time | 180min/20pcs (traditional mode),100 min/20pcs(fast mode) | 100 min/20pcs (fast mode) | 240 min/20pcs | 240 min/10pcs | |
Automatic sample sending | √ | ||||
MCPC module | √ | ||||
Built in balance | √ | ||||
Balance display module | √ | ||||
Working power | AC 220V±22V/50Hz | ||||
Power | ≤6kW | 4kw | 2kw | 4kw | 4kw |
Overall dimensions | 630×560×580mm 560×560×750mm |
630×560×580mm |
560×560×750mm | 630×560×580mm | 630×560×580mm |
Net weight | 90kg/80kg | 90kg | 80kg | 90 | 90 |