Portable Turbidity Meter with LED Source ISO7027 DIN27027

Product Details
Customization: Available
After-sales Service: Life Time
Warranty: 24 Months Free
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory, Trading Company
Secured Trading Service
Gold Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

In-stock Capacity
The supplier has In-stock capacity
Fast Delivery
The supplier can deliver the goods within 15 days
Low MOQ
The MOQ for the supplier's products is 1
Customization from Samples
The supplier provides sample based customization services
to see all verified strength labels (15)
  • Portable Turbidity Meter with LED Source ISO7027 DIN27027
  • Portable Turbidity Meter with LED Source ISO7027 DIN27027
  • Portable Turbidity Meter with LED Source ISO7027 DIN27027
  • Portable Turbidity Meter with LED Source ISO7027 DIN27027
  • Portable Turbidity Meter with LED Source ISO7027 DIN27027
  • Portable Turbidity Meter with LED Source ISO7027 DIN27027
Find Similar Products

Basic Info.

Model NO.
EC-TN
Display
Digital
Appliance
Food Analysis, Medical Research, Biochemistry
Portable
Portable
Certification
CE, ISO9001
Type
Turbidity Meter
Application
Liquid Turbidity Measurement
Categroy
Electro-Chemical Instrument
Standards
ISO7027
Function
Liquid Turbidity Test
Transport Package
Carton Case
Specification
EC-TB100
Trademark
SRL
Origin
China
HS Code
9031809090
Production Capacity
1000sets/Month

Packaging & Delivery

Package Size
30.00cm * 30.00cm * 30.00cm
Package Gross Weight
5.000kg

Product Description

Portable Turbidity Meter with LED Source ISO7027 DIN27027

The EC-TN100&EC-TN450 portable turbidity meters comply with the new national standard turbidity meter method. The instrument design adopts the scattering principle and complies with the ISO7027 standard. It is used to measure the turbidity of aqueous solutions, especially colored aqueous solutions such as grape containers and fruit juices, and is suitable for laboratory or on-site use.
 

 

 Features

Commons features of ECA-TN100 & TN450
The instrument adopts 90 ° scattered light measurement, LED light source (referred to as red light), wavelength 860 ± 30nm, and complies with HJ 1075-2019, ISO7027, and DIN27027 standards. It is used to measure the turbidity of aqueous solutions and is suitable for laboratory or on-site use. The red light source is not affected by the color of the solution and can be used for turbidity measurement of colored solutions.
Support intelligent functions such as automatic calibration, operation navigation, menu settings, automatic shutdown, and low voltage indication
Standard long-acting polymer calibration solution solution, certified by EPA and ASTM, with a one-year validity period, safe and non-toxic, no preparation required, and easy to use.
0~1000NTU automatic range switching
Continuous measurement mode: It can continuously measure 10 times to display the average value, improving measurement accuracy, especially suitable for sample solutions with rapid sedimentation and continuous changes in measurement values.
Large TFT color display screen with multilingual text navigation (Chinese, English, Spanish), easy to operate.
Meet the sealing level requirements of IP67, suitable for outdoor and on-site use.
Equipped with a dedicated suitcase containing a complete set of accessories such as calibration solutions and test bottles, it is more convenient to carry and use.

Exclusive features of EC-TN450
 Support intelligent functions such as automatic calibration, operation navigation, menu settings, real-time clock display, viewing calibration time, automatic shutdown, and low voltage indication.
TruRead reading mode: can set the number of consecutive measurements, display all measured values on one interface, generate maximum, minimum, and average values, and store the measurement interface. It can improve measurement accuracy, especially suitable for sample solutions with rapid sedimentation and continuous changes in measurement values.
Zero turbidity error reminder function: The instrument has a zero calibration function and a zero error reminder to ensure the measurement accuracy of low turbidity solutions.
200 sets of GLP data storage, echo, deletion, USB signal output.
 

Specifications

Model EC-TN100 EC-TN450
Measuring  method 90 ° scattered light measurement, in accordance with HJ 1075-2019, ISO7027 and DIN27027 standards. 90 ° scattered light measurement, in accordance with HJ 1075-2019, ISO7027 and DIN27027 standards.
Light source Infrared light-emitting diode (wavelength 860 ± 30nm) Infrared light-emitting diode (wavelength 860 ± 30nm)
Measuring range 0 ~ 1000 NTU(FNU), auto shift
0.01~19.99 NTU(FNU)
20.0~99.9 NTU(FNU)
100~1000 NTU(FNU)
0 ~ 1000 NTU(FNU), auto shift
0.01~19.99 NTU(FNU)
20.0~99.9 NTU(FNU)
100~1000 NTU(FNU)
Indication error ±8% ±6%
Repeatability ± 1.0% ± 0.5
Zero drift ± 0.5FS/30min ± 0.5FS/30min
Stability ± 1.0FS/30min ± 0.5FS/30min
Resolving power 0.01 / 0.1 / 1 NTU(FNU) 0.01 / 0.1 / 1 NTU(FNU)
Calibration standards Polymer solution or Formazin solution: 0, 20, 100, 400, and 800NTU (FNU) Polymer solution or Formazin solution: 0, 20, 100, 400, and 800NTU (FNU)
detector silicon photocell Silicon photocell
Measurement mode Normal mode (key reading) and average measurement mode Normal mode (key reading) and TruRead mode
Data storage / 200 units
Signal output / USB
Calibration record / Can view calibration date and time
display TFT color display screen TFT color display screen
Sample bottle Φ twenty-five × 60mm, high borosilicate glass, with bottle cap. Φ twenty-five × 60mm, high borosilicate glass, with bottle cap.
Sample capacity 18 ml 18 ml
Power Supply 4 AA batteries 4 AA batteries
Working conditions Temperature: 0-50 ºC; Relative humidity: 0-90% at 30 ºC, 0-80% at 40 ºC, 0-70% at 50 ºC, non condensing Temperature: 0-50 ºC; Relative humidity: 0-90% at 30 ºC, 0-80% at 40 ºC, 0-70% at 50 ºC, non condensing
Storage conditions Instrument: -40~60 ºC, calibration solution: 5~30 ºC Instrument: -40~60 ºC, calibration solution: 5~30 ºC
Instrument sealing level IP67 IP67
Quality and Certification ISO9001:2015 and CE ISO9001:2015 and CE
Quality guarantee period Instrument 2 years (from purchase date), calibration solution 1 year (from factory date) Instrument 2 years (from purchase date), calibration solution 1 year (from factory date)
Size and weight Instrument: (90 ×203 × 80) mm/385 g Carrying case: (310 × 295 × 110)mm / 1.5 kg Instrument: (90 ×203 × 80) mm/385 g Carrying case: (310 × 295 × 110)mm / 1.5 kg
 

Standard configurations

EC-TN100 EC-TN450
Calibration solution: 0.0, 20.0, 100, 400, and 800NTU Calibration solution: 0.0, 20.0, 100, 400, and 800NTU
suitcase suitcase
Master machine Master machine
Soft cloth Soft cloth
Small screwdriver Small screwdriver
Silicone oil (10 ml) USB drive
Battery Battery
Sample bottle × six Silicone oil (10 ml)
instructions Sample bottle × six
/ USB communication cable (below the instrument panel)
/ instructions
Portable Turbidity Meter with LED Source ISO7027 DIN27027Portable Turbidity Meter with LED Source ISO7027 DIN27027Portable Turbidity Meter with LED Source ISO7027 DIN27027Portable Turbidity Meter with LED Source ISO7027 DIN27027Portable Turbidity Meter with LED Source ISO7027 DIN27027Portable Turbidity Meter with LED Source ISO7027 DIN27027Portable Turbidity Meter with LED Source ISO7027 DIN27027

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More