The temperature shock test chamber is used to test the temperature shock resistance of various materials, the temperature shock resistance of material is obtained by the applicability under extremely high and low temperature condition, thus to know the material and products quality. The temperature shock test chamber is kind of very common environmental test chamber.
GB/T2423.1-1989low temperature test method
Model | CT-TCJ27 | CT-TCJ50 | CT-TCJ 80 | CT-TCJ 150 | CT-TCJ 225 | |
Internal volume(L) | 27 | 50 | 80 | 150 | 225 | |
Internal size(cm) | 30×30×30 | 35×40×35 | 40×50×40 | 50×60×50 | 60×70×60 | |
Overall size(cm) | 110×115×160 | 135×125×180 | 147×135×150 | 192×155×160 | 220×165×170 | |
High temperature chamber | Preheat temperature range 60~+200ºC, heating rate 35min | |||||
Low temperature chamber | Precool temperature range -55/-65~-10ºC, cooling rate 55min | |||||
Test temperature range | -40,-55,-65~+150ºC( can be tailor made) | |||||
Temperature recovery time | Approx. 3~5min | |||||
Material | Internal material | SUS304 steel sheet | ||||
Enclosure material | SUS304 drawbench steel sheet or antirust processing cool rolling steel sheet with plastic sprayed | |||||
Heat insulation material | Ultrafine glass cotton+ polyamine foam | |||||
Construction | High temperature chamber | Heater: nichrome electric heating wire heater, heat storage device | ||||
Fan: centrifuge fan and axial flow fan | ||||||
Low temperature chamber | Heater: nichrome electric heating wire heater, heat storage device | |||||
Chiller: finned heat exchanger, chiller | ||||||
Fan: centrifuge fan | ||||||
Driving unit | Pneumatic air cylinder | |||||
Air compressor(optional) | ||||||
Refrigeration unit | Refrigeration method: mechanical dual overlap mode | |||||
Compressor | Internal brand original import, full or semi sealed compressor, no noise | |||||
Refrigerant | Environment friendly r-507/r-23a | |||||
Evaporimeter | Finned heat exchanger, chiller | |||||
Condenser | SUS braze plate heat exchanger | |||||
Controller | Operation menu | OYO or YEMI original imported colorful LCD | ||||
Running mode | Constant & programmable | |||||
Program volume | 120 unit program, each program max 999 sections | |||||
Set value range | Temperature:-100ºC+300ºC | |||||
Resolution | 0.1ºC | |||||
Input | Pt100, t type thermal couple | |||||
Control mode | PID | |||||
Communication function | RS-232 | |||||
6 point recorder(optional) | ||||||
Other functions | Up low limit alarm, self diagnose, alarm indication(error cause), timing (automatic start, off) | |||||
Standard configuration | 1 observe window, 1 50mm test hole, sample frame, spotlight 1pc | |||||
Auxiliary functions | Timer, over temperature protection, sensor up down wind selection, power failure protection, alarm record, test curve record, test suspend, running time indication | |||||
Safety device | RCCB, over temperature, low temperature protection, air vent valve, sample power supply control terminate, compressor over pressure, overheat protection, water supply cut off breaker, fan hot breaker, motor temperature switch, motor anti-reverse breaker, compressed air pressure gauge, fuse |