Customization: | Available |
---|---|
After-sales Service: | Life Time |
Warranty: | 24 Months Free |
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
It is specialized to determine the content of carbon, hydrogen and nitrogen in solid materials such as coal and coke.
39 samples can be set out at one time, and 78 samples can be purchased at one time. The instrument can automatically send samples, set samples, and conduct cyclic testing. The whole process does not require manual operation after setting out, and samples can be added, subtracted, and replaced at any time during the analysis process;
The horizontal structure is adopted, and the instrument can be placed on the laboratory table, which is convenient for customers to operate;
The advanced PID algorithm is used to control the temperature, the furnace temperature control accuracy can reach ± 1 ºC, and the temperature control accuracy of the thermostatic chamber and the air tank can reach ± 0.1 ºC;
The absolute pressure sensor is used to monitor the pressure of the whole gas path of the instrument, which can automatically detect the air tightness of the whole gas path and the furnace, infrared pool, thermal conductivity pool, and gas storage tank;
The instrument adopts infrared spectrum absorption method to determine carbon content and hydrogen content, and thermal conductivity method to determine nitrogen content;
Fast test speed, high degree of automation, and the time for testing carbon, hydrogen and nitrogen is about 4 minutes;
During the experiment, the option of "automatic cooling after the experiment" can be selected. After the experiment is completed, the computer will automatically shut down and the instrument will automatically cool down. No one can be on duty. No personnel are required to manually cool down and shut down after the test is completed;
The experimental report can be prepared according to the customer's requirements to reduce the customer's workload;
It can be connected to the laboratory management system to ensure that the balance data does not fall to the ground, and the test results are backed up and uploaded.
Model | MJ-ECA-CHN | MJ-ECA-CH | MJ-ECA-H | MJ-ECA-HM | |
Measure range | C:0.005%~100%,H:0.01%~60%,N:0.008%~60% | C:0.005%~100%, H: 0.01%~60% | H:0.01%~60% | H:0.01%~20% | |
Method | Infrared spectral absorption thermal conductivity method | Infrared spectral absorption | Coulomb method | ||
Repeatability | C(Cad≤0.5%),H(Had≤0.15%),N(Nad≤0.08%) | C(Cad≤0.5%),H(Had≤0.15%) | H(Had≤0.15%) | H(Had≤0.15%) | |
Accuracy | Within the uncertainty range of the standard sample | ||||
Temp. range | RT+10~1050ºC, ±1ºC | RT+10~850ºC, ±1ºC | |||
Sample quantity | Recommend 80~100mg | 70±5mg | |||
Sample feeding | Automatic | Manual | |||
Sample quanatity | 39 Pieces/batch, add/replace samples during the test, and purchase 78 sample trays for one-time setting out | 1 | |||
Single sample process time | 4min | 8-15mins | |||
Carrier gas | Helium, purity ≥ 99.995%, pressure 0.25 ± 0.1MPa | / | |||
Auxiliary gas | Oxygen, purity ≥ 99.5% when measuring hydrocarbon element, purity ≥ 99.995% when measuring nitrogen element, pressure 0.25 ± 0.1MPa | Oxygen purity≥99.5% | |||
Power gas | Inert gas, no oil, no water, pressure 0.29±0.1MPa | / | |||
Power | ≤4.5kw | ||||
Power supply | 220VAC±10%, 50HZ | ||||
Type | Horizontal (can be placed on table) | Horizontal | |||
Overall dimensions(mm) | 690×740×720 | 690×740×720 | 690×740×720 | 920×470×440 | |
Net wight(kg) | 105 | 102 | 102 | 47 |
Automatic proximate analyzer