Infrared Method High Frequency Carbon Sulfur Analyzer Carbon Sulfur Analytical Instrument Tgy-3

Product Details
Customization: Available
After-sales Service: Lifetime
Warranty: 1 Year
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory, Trading Company
Secured Trading Service
Gold Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

In-stock Capacity
The supplier has In-stock capacity
Fast Delivery
The supplier can deliver the goods within 15 days
Low MOQ
The MOQ for the supplier's products is 1
Customization from Samples
The supplier provides sample based customization services
to see all verified strength labels (15)
  • Infrared Method High Frequency Carbon Sulfur Analyzer Carbon Sulfur Analytical Instrument Tgy-3
  • Infrared Method High Frequency Carbon Sulfur Analyzer Carbon Sulfur Analytical Instrument Tgy-3
  • Infrared Method High Frequency Carbon Sulfur Analyzer Carbon Sulfur Analytical Instrument Tgy-3
Find Similar Products
  • Overview
  • Product Description
  • Technical Specifications
  • Features
  • Key components
  • Detailed information
  • Company Profile
  • Detailed Photos
Overview

Basic Info.

Model NO.
TGY-3
Element
Computer Multi Element Analyzer
Analysis
Infrared Analysis
Display
Computer Screen
Application
Sulfur and Carbon
Frequency
18-20MHz
Performance
Automation
Function
Analyze
Weight
100-500Kg
Power Source
AC220V±22V
Customized
Non-Customized
Shipping Way
Air, Sea, Land
Delivery Time
5-7 Working Days
Supply Area
Global
Analysis Time
Adjustable From 25 to 60 Seconds
Transport Package
Wooden Case
Specification
FX-HW2000B
Trademark
SERVE REAL
Origin
China
HS Code
9031809090
Production Capacity
500PCS/Year

Packaging & Delivery

Package Size
40.00cm * 45.00cm * 50.00cm
Package Gross Weight
100.000kg

Product Description

Infrared method high frequency carbon sulfur analyzer
Product Description

The FX-HW2000B infrared carbon and sulfur analyzer is used in conjunction with the GP2000 high-frequency induction combustion furnace to quickly and accurately determine the mass fractions of carbon and sulfur in steel, iron, alloy, casting core sand, non-ferrous metals, cement, ore, coke, catalyst, and other materials. It has the characteristics of wide measurement range, strong anti-interference ability, high stability, simple operation, fast analysis speed, accurate and reliable results, and is an excellent cost-effective furnace front rapid analysis instrument.

Innovations

The innovation of instrument design not only includes infrared technology, but also integrates ergonomics and practical design concepts. The humanized integrated tabletop design eliminates the need for users to configure a workbench, making each display process relatively centralized. Not only is the operation natural and comfortable, but it is also easy to install and replace components, safe and simple to operate, and reduces maintenance workload. The instrument is equipped with casters, which can be easily moved to other positions during maintenance.

Technical Specifications

1. Analyze materials: various solid raw materials such as ferrous metals, non-ferrous metals, alloys, carbides, rare earth metals, minerals, etc.

2. Measurement range: Carbon: 0.00001% -99.999%
Sulfur: 0.00001% -99.999%
3. Analysis accuracy: Carbon RSD ≤ 0.5% Sulfur RSD ≤ 1.0% Flexibility (minimum reading) 0.1ppm
4. Analysis time: adjustable from 25 to 60 seconds
5. Analysis standard: Both carbon and sulfur comply with GB/T2013-2006/ISO15350:2000 standard
6. Electronic balance weighing accuracy: 0.0001g
7. High frequency furnace: Power: 2.5KVA Frequency: 18-20MHz

 
Features

1. The high-frequency furnace adopts radio frequency heating technology, truly ensuring the consistency of each combustion and ensuring the stability of testing;

2. Possess the top-notch carbon and sulfur analysis technology from the German family, using high-performance narrowband filters to avoid interference from high carbon on sulfur;
3. The imported high-precision infrared pyroelectric detector ensures the precision and accuracy of high carbon and ultra-low carbon measurements;
4. The infrared carbon and sulfur absorption device adopts an aviation synchronous motor imported from Switzerland, which can ensure continuous use for 100000 hours without faults;
5. Military grade motherboard design and modular application, combined with temperature, pressure, and flow compensation technology, ensure the consistency of analysis results;
6. The application of high-precision flow control and 200000 faultless opening of the Taiwan Yadeke solenoid valve ensures the reliable operation of the gas circuit.
7. Strong combination of provincial high-tech products and national key new products;
8. Military grade motherboard design and modular application, with high reliability;
9. Fiber optic transmission interface, strong anti-interference, and stable data;
10. Fully automatic furnace head design, automatic double-sided reverse blowing, effectively removing dust after combustion, especially suitable for the stability of analyzing multi dust samples such as raw materials;
11. Advanced and reasonable analysis software, open database, convenient for users to manage and analyze data themselves;
Key components

 

Hardware
The infrared detection cell designed with dual carbon and dual sulfur ensures accurate measurement results Infrared Method High Frequency Carbon Sulfur Analyzer Carbon Sulfur Analytical Instrument Tgy-3IR Detection cell
Light source: A specially designed new platinum infrared light source with continuous heating and good spectral characteristics.

Analysis cell: gold-plated carbon sulfur analysis cell and high-precision pyroelectric infrared detector (up to 10-11).

Motor: Aviation specific modulation motor with good thermal stability and a continuous service life of 100000 hours.

Signal: Adopting a high impedance operational amplifier circuit, coupled with a high-performance demodulation system and filtering circuit.

Temperature control: The gas chamber maintains a constant temperature to ensure the impact of environmental changes on measurement results.

Communication: The upper and lower computers use USB2.0 interface communication, greatly improving communication speed.

Connection: The infrared detection part is connected to the high-frequency furnace using optical fiber (pioneered in China), combined with multi-level concealed isolation circuits, completely eliminating high-frequency interference.
Modular whole machine, convenient and reliable automation operation Infrared Method High Frequency Carbon Sulfur Analyzer Carbon Sulfur Analytical Instrument Tgy-3
Power supply: A high-performance, high-quality, and low loss specially designed switching power pack with stable input and built-in multiple protection circuits.
Circuit: Adopting a dual CPU system, with modular design for upper and lower computers. The lower computer uses Atmega162 as the control microcontroller, and the electronic circuit is highly integrated, stable and reliable.
Sampling: Adopting a high-speed 24-bit ADS124 sampling chip, the sampling speed is fast and the accuracy is high.
High reliability high-frequency combustion system Infrared Method High Frequency Carbon Sulfur Analyzer Carbon Sulfur Analytical Instrument Tgy-3


 
High-frequency circuit

High power high-frequency circuit design, using 7.5KVA high-frequency ceramic power tubes (actual usage power greater than 2.5kVA, no sample air burning can be added), reducing the load on the high-frequency combustion system and improving its service life.
safety control Infrared Method High Frequency Carbon Sulfur Analyzer Carbon Sulfur Analytical Instrument Tgy-3
Automatically detect the electromagnetic valve, lifting cylinder, and high-frequency working conditions to protect the high-frequency furnace from working normally.

Air Path

High precision flow controller and imported air circuit system (solenoid valve, pipe joint, lifting cylinder) ensure stable airflow.
Dust removal system
The exclusive dust backflow prevention air system greatly extends the service life of the equipment.
0.4 micron ultra micro porous metal filter, automatic cleaning of furnace head, and imported ash discharge system to reduce the impact of dust on the analysis results.
The low-pressure heating ring with specialized technology heats the furnace head, improving the sulfur conversion rate and stabilizing the sulfur analysis results.
Infrared Method High Frequency Carbon Sulfur Analyzer Carbon Sulfur Analytical Instrument Tgy-3
Software
Based on the WINDOWS system, the infrared carbon sulfur dedicated software displays relevant data such as pool voltage and weight on the screen. It is equipped with a Chinese menu structure, navigation style operation, and other optimized designs, making it easy to use without any professional knowledge. Infrared Method High Frequency Carbon Sulfur Analyzer Carbon Sulfur Analytical Instrument Tgy-3
      



Main interface and carbon and sulfur release curve

      

Channel index
Infrared Method High Frequency Carbon Sulfur Analyzer Carbon Sulfur Analytical Instrument Tgy-3
 

      
 
The system establishes a complete set of linear data, which can be corrected using control samples and can directly perform breakpoint correction.
Operating software: Compiled using Deliph software, Windows XP all Chinese operating software
Analysis function: Dynamic data integration during the analysis process, 24 samples per second, improving the sensitivity and accuracy of the analysis
Dynamic data integration, dynamically displaying real-time data and carbon and sulfur release curves during the analysis process.
Provide sample management function, which allows for editing of sample names and identifiers, as well as adding and deleting sample names; The software provides a multi user management system, which allows administrators to set different user permissions
Display function: One curve box for carbon and sulfur, dynamically displaying real-time data and carbon and sulfur release curves during the analysis process
Data processing function: The analysis results are stored in the ACCESS database, which can store all data and curves of carbon and sulfur for each analysis; The analysis results can be freely queried based on multiple factors such as time, operator, sample name, identification, etc; Provide multiple functions such as curve/data storage, blank deduction, parameter setting, channel selection, mathematical statistics, result correction, curve comparison, etc; The generation of carbon and sulfur working curves and curve fitting can be achieved in software.         StatisticsInfrared Method High Frequency Carbon Sulfur Analyzer Carbon Sulfur Analytical Instrument Tgy-3
Analysis channel: Provides channel management function, where carbon and sulfur channels can be added, deleted, and edited on their own, with no quantity limit. Low carbon and high sulfur interfaces are preset, and software automatic switching can be achieved.
Data can be transmitted over long distances to achieve data reporting in front of the furnace.
Other configurations
Computer Printer Electronic balance
·Model: HP
·Processor: CPU AMD A6-9500 dual core,
·Memory: 4G
·Hard drive 500G
·Display 19 inch LCD
·Model: HP laser printer
·Resolution 2400 * 600dpi
·Monthly printing load of 2000 pages
·Automatic printing mode
·Model: FA114
·Maximum weighing (g): 100
·Minimum reading (mg): 0.1
·Linear error (mg): ≤ 0.2
Detailed information

Service Terms

1. Supply:
Delivery time for domestic users: Within three working days after payment;
Delivery time for foreign users: Within seven working days after payment;
2. Equipment installation and on-site services
1) Requirements and regulations for unpacking after delivery
After the instrument arrives at the user's site, prepare the laboratory as required and notify the manufacturer in writing of the installation and commissioning requirements.
When delivering and unpacking, both the factory representative and the user representative must be present on site to inspect the items according to the contract list and make necessary records of the quantity and appearance of the goods. After unpacking, the equipment must be installed immediately; Otherwise, sealing strips agreed upon by all parties must be used for storage and placed indoors in a closed and dry cement floor with a temperature of 10-30 ° C; The humidity is ≤ 75%.
2) On site installation services
After receiving notification of customer installation requirements, the installation personnel will come to the site for installation at the agreed time and provide the following on-site services:
Open the box together with the user representative and inspect the goods against the packing list
Before turning on the power, open the instrument cover and thoroughly inspect for any internal damage caused by transportation
Check whether the peripheral supporting equipment prepared by the laboratory and users is complete and meets the requirements
Install instruments and connect peripheral devices
Connect the instrument to the power supply
Run a typical operating process to verify the normal operation of the instrument
Check the factory calibration program and analysis program
On site training for users and equipment handover.
3. Acceptance:
Based on the contract, conduct inventory and acceptance according to the specified supply scope or refer to relevant national standards for acceptance;
Analyze the accuracy, use random standard samples for accuracy assessment, and ensure that the acceptance indicators meet the contract requirements. Use randomly attached calibration standards or user provided standards for quality inspection and acceptance.
4. Handover
The instrument indicators meet the contract requirements and the analysis system operates normally; The performance and supply scope of the instrument comply with the contract description; The acceptance report shall be signed by representatives of both parties to complete the equipment handover.
Remarks:
The total working time for installation, debugging, training, and acceptance at the user's site shall not exceed 3 days; Additional support for working days will be charged separately; The handover of equipment shall end with equipment acceptance.
Acceptance shows the normal operation of the analysis system, and the instrument performance and supply scope meet the contract description. Representatives of both parties sign the acceptance report.
Before installation, the buyer must prepare according to the installation conditions and requirements provided by the seller. If the installation acceptance work is not completed due to this, additional fees will be charged for the installation acceptance again.
Due to insufficient preparation by the buyer, the installation and commissioning of the instrument have been delayed. The remaining payment for the instrument will be paid within one month of delivery.
5. Quality assurance, training, and services
Provision of technical documents
The supplier shall send the installation condition manual within two weeks after the contract takes effect;
Provide a set of operation analysis software and a set of Chinese manuals with the instrument, including hardware configuration, software functions, operation instructions, installation and maintenance. Random working curve raw data. Factory quality certificate, packing list, etc.
Warranty period
The warranty period is 12 months after acceptance or 15 months from the date of delivery, whichever comes first.
Except for damages caused by improper use by users, during the warranty period, the company is responsible for free repair or replacement of corresponding damaged parts for users.
Outside the warranty period, the supplier continues to provide high-quality services to users.
Technical training and services
The company has a dedicated customer service department that provides pre-sales and after-sales services to customers; Equipment maintenance and repair shall be carried out by professional technical engineers; Respond within 24 hours after receiving user fault notification; Need to arrive at the user's site within 72 hours nationwide; Both parties shall agree beyond the warranty period, and the warranty period shall be executed according to the contractual agreement between both parties.
The company is responsible for providing on-site operation, calibration, maintenance, and common fault handling training to user personnel during installation and debugging.        
Customer examples(part of)
1. Research institutes
Institute of Physics, Chinese Academy of Sciences, Nanjing University of Technology, Beijing University of Aeronautics and Astronautics
Quzhou Quality and Technical Supervision Bureau of Northeastern University of South China University of Technology
Kunming New Materials Research Institute of Nanjing Institute of Engineering, China Construction Quality Testing Center
Anhui Lu'an Technical Supervision Bureau, Shaanxi Agricultural University of Science and Technology, Jiangsu Engineering Quality Inspection Institute, Liyang Testing Center
Shaanxi Nuclear Industry 203 Research Institute Zhejiang University of Technology Zibo Vocational and Technical College Fujian Provincial Testing Engineering Testing Center Laiwu Vocational and Technical College Guizhou Mechanical and Electronic Product Quality Supervision and Testing Institute
2. Large state-owned enterprises
China Ordnance Shandong Special Industry Group Yankuang Group Puyang Longyuan Power Group Co., Ltd
Shaanxi Qinhang Machinery Manufacturing Co., Ltd. Shaanxi Baoshen Group Sany Heavy Industry
CNOOC XCMG Group China FAW
Ansteel Group, Wuhan Iron and Steel Group, Masteel Group
Weichai Power Jinan Second Machine Tool Group China Railway Construction
China Aerospace China Southern Power Grid Shenyang Machine Tool Group
Northwest Forestry Design Institute of the State Forestry Administration
3. Industry renowned enterprises
Shandong Dachai Cylinder Head Co., Ltd. Chiping Xinfa Group Shandong Weiqiao Entrepreneurship Group Shaanxi Qinhang Machinery Manufacturing Co., Ltd. Shaanxi Baoshen Group Leshan Weidong Machinery Manufacturing
Zhuji Wan'an Technology Ningbo Beilun Cylinder Liner Association Ningbo Wandu Automotive Parts
Jiaxing Hongfeng Machinery Henan Qinyang First Paper Machinery Luoyang Zhongsi High tech
Henan Xinxiang Yuanyang Universal System Manufacturing Chery Automobile Shanxi Changzhi Hydraulic System
Zhongyuan Lida Railway Technology Hebei Jianzhi Casting Group Yixing Yingpu Machinery
4. International and regional enterprises
Hong Kong Testing Center Taiwan Green Crystal Energy Co., Ltd. Samsung Precision Machinery Co., Ltd. Russia Strong Group Malaysia Anyu Resources Co., Ltd. Brazil Woodbrook Transmission System Group Saudi Arabia Testing Center Russia Vodka Automobile Group Brazil National Machinery Heavy Industry Group
 
Company Profile

Who we are
We are professional manufacturer & supplier specialized in Civil Engineering & Material testing equipments since 2003. We can supply various kinds of testing equipments that complies to the following standards ASTM/AASHTO, ISO, EN, DIN  JIS, as well as other specialized industry standards. Meanwhile we are authorized oversea market distributer of some famous China testing equipments manufacturer. Our customers come from 6 Continents with more than 90 countries & area since company has been established.

Our advantages
1. Quality assurance--We aim to long term cooperation with every of our customer
2. Reasonable price -- we believe only reasonable price can guarantee reliable quality & service
3. Wide range products--we not only sale own products but also acting products of mulity famous China manufacturers, time saving, easier process, better quality & price, guaranteed service.
4. After-sales service guaranteed--all sold products enjoy 12 months warranty period since products claimed, free spare parts (the transportation cost payment depends on the weight & destination).
5. Fast response & professionalism-- 7/24 response either on sales inquiry or after-sales service, Monday to Friday response within 2 hours, weekend response within 6hours.
6. Multi payment modes--Wire transfer (T/T), Paypal (credit card), Western Union, L/C.

Detailed Photos

Infrared Method High Frequency Carbon Sulfur Analyzer Carbon Sulfur Analytical Instrument Tgy-3

      Infrared Method High Frequency Carbon Sulfur Analyzer Carbon Sulfur Analytical Instrument Tgy-3 
- SERVE REAL INSTRUMENTS INTRODUCTION

Infrared Method High Frequency Carbon Sulfur Analyzer Carbon Sulfur Analytical Instrument Tgy-3
Infrared Method High Frequency Carbon Sulfur Analyzer Carbon Sulfur Analytical Instrument Tgy-3
Infrared Method High Frequency Carbon Sulfur Analyzer Carbon Sulfur Analytical Instrument Tgy-3

Infrared Method High Frequency Carbon Sulfur Analyzer Carbon Sulfur Analytical Instrument Tgy-3Infrared Method High Frequency Carbon Sulfur Analyzer Carbon Sulfur Analytical Instrument Tgy-3

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More